IJUAhsCC::CC - Specifies the distance between the centerlines of the rods connected to a type G spring.
IJUAhsLoad::Load - Specifies the actual load supported by the constant support.
IJUAhsMovement::Movement - Specifies the amount of thermal displacement of the pipe when moving from the installed (cold) to operating (hot) conditions.
IJUAhsMovementDir::MovementDirection - Specifies the direction of the displacement when moving from the installed to operating conditions. It uses codelist value defined in the hsSpringMovementDir sheet of the HS_S3DParts_Codelist.xls workbook.
IJUAhsTTIncrement::TTIncrement - Specifies the increments between total travels. For example, if total travel goes up in ½ inch increments, set this value to 0.5.
IJUAhsTTIncrementByRule::TTIncrementByRule - Specifies the rule that the software uses to get the total travel increment value. The total travel increment value from the TTIncrementByRule overrides TTIncrement value.
IJUAhsTTUnitType::TTUnitType - Specifies the units of the total travel.
IJUAhsOverTravelMin::OverTravelMin - Specifies the minimal amount that the total travel must exceed the movement/actual travel.
IJUAhsOverTravelPercent::OverTravelPercent - Specifies the percentage amount that the total travel should be greater than the movement.