IJOAhsPipeOD::PipeOD

Specifies the outside diameter the pipe to which saddle is connected.

IJUAhsRadius1::Radius1

Specifies the outer radius of the saddle measured from the center of the pipe to the bottom of the saddle.

If Radius1=0 then the software sets Radius1 = (PipeOD/2) + Thickness2 + Thichness1 to the default value for this property.

IJUAhsThickness1::Thickness1

Specifies the thickness of the saddle. It is always greater than zero.

IJUAhsInclStiffener::InclStiffener

Indicates whether or not to include the middle plate. If this value is set to Yes, then the middle plate is drawn. This property uses the codelist value defined in the hsYesNo sheet in the HS_S3DParts_Codelist.xls.

IJUAhsThickness2::Thickness2

Specifies the thickness of the insulation.

IJUAhsLength1::Length1

Specifies the length of the plate. It is always greater than zero.