Port Details - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
Hangers and Supports
Search by Category
Reference Data
Smart 3D Version
13

These properties are used to specify the different port types and their sizes for the clevis

Clevis

Port1 - Pin or Hole Location (0, 0, 0)

PortType

Size

MinSize

MaxSize

1005 -- Pin
(or)
1007 -- Eye

Pin -- Pin1Diameter

Hole -- Hole Diameter

Use 0

Pin -- Pin1Diameter

Hole -- Hole Diameter

Port2 - RodEnd Location: (0, 0, RodTakeOut)

PortType

Size

MinSize

MaxSize

1001 – IntThdRH
(or)
1003 – IntThdLH

  • The diameter of the rod that connects other components.

  • Enter the same value as RodDiameter.

Use 0

Use 9999

Port3 - Surface Location: (0, 0, Opening1 + Thickness1)

PortType

Size

MinSize

MaxSize

1200 – Other

Not applicable for this type port. Use 0.

Not applicable for this type port. Use -9999.

Not applicable for this type port. Use 9999.