Library Name: SmartParts
Workbook: HS_S3DParts.xls
Codelist: HS_S3DPArts_Codelist.xls
ProgID: HSSmartPart,Ingr.SP3D.Content.Support.Symbols.ConstantLoadColumn
Part Name: Constant Load Column
Part Description: Constant Load Column SmartPart
Prerequisites
Make sure that the following workbooks in [Product Folder]\CatalogData\BulkLoad\DataFiles\ are already bulkloaded.
-
AllCodeLists.xls
-
AllCommon.xls
-
GenericNamingRules.xls
-
HS_System.xls
-
HS_System_Codelist.xls
-
HS_S3DParts_Codelists.xls
Part Placement
To place a sample constant load column SmartPart delivered with the catalog:
-
Click Tasks > Hangers and Supports.
-
Place a design support on a pipe.
-
Click Place Part , and then select the design support.
-
In the Select Part dialog box, select a part from Parts > SmartParts > S3D Standard > Constant > Constant Load Column as shown below:
Part Properties
Millimeters (mm) is the default unit. Use in at the end of dimensional values to specify inches. Ports are shown as points highlighted in red .
ProgID
HSSmartPart,Ingr.SP3D.Content.Support.Symbols.ConstantLoadColumn
Example: S3Dhs_CONST_COL sheet in HS_S3DParts.xls
Local Coordinate System
Constant Part Properties
IJUAhsLoad::Load
Specifies the load of the load column. The load value must be greater than or equal to zero. This value is required.
IJUAhsMovement::Movement
Specifies the movement of the load column. This value is required.
IJUAhsMovementDir::MovementDirection
Specifies the direction of movement for the load column. Accepted values are Up and Down. This property uses the codelist value defined in the hsSpringMovementDir sheet of the HS_S3DParts_Codelist.xls workbook.
Port Details
These properties specify the different port types and their sizes for the constant load column.
Hole 1 - Hole1
The hole ports are aligned so that they easily connect to the pipe. The X axis of the route port is aligned along the length of the insulation, and the Z axis is pointing in the downward direction.
PortType |
Size |
MinSize |
MaxSize |
1009 - Double Lug |
Use -1 |
Use -9999 |
Use 9999 |
Hole 2 - RodEnd
The rod end is aligned so that it easily connects to the pipe. The X axis of the route port is aligned along the length of the insulation. The Z axis should point in the downward direction.
PortType |
Size |
MinSize |
MaxSize |
---|---|---|---|
1001 - External Thread, RH |
Use -1 |
Use -9999 |
Use 9999 |
Top 1 - Surface
The surface is aligned so that it easily connects to the pipe. The X axis of the route port should be aligned along the length of the insulation. The Z axis should point in the downward direction.
PortType |
Size |
MinSize |
MaxSize |
---|---|---|---|
1200 - Other |
Use -1 |
Use -9999 |
Use 9999 |