Face Selection Sheet - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Hangers and Supports Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Hangers and Supports
Search by Category
Reference Data
Smart 3D Version
13.1
Standard Database for Smart Reference Data Version
2020 (12.0)

The Face Selection sheet in the HS_System.xls workbook defines the faces of a structural member to which a part can attach itself.

Face Name

Type a unique name for the face selection option. This name must be unique across the entire catalog.

Description

Type a description for the face selection option.

Cross Section

Type the cross section shape to which the face selection option applies. For example, W or L.

Selection Key

Type a code to link this face selection option to parts. All face selection options with the same selection key code, 1 for example, is made available to the part that has this code defined. The default key is 1000.

Face 1

Type the member face with the highest priority. This face is default when the assembly is placed.

Group 1

Type the group key code. Valid codes are listed on the Face Position Selection sheet in the Group Key column. For more information about this code, see Face Position Selection Sheet.

Face 2

Type the member face with the next highest priority. This face is the second choice when the assembly is placed. Type 0 if you do not want to define another choice.

Group 2

Type the group key code. Valid codes are listed on the Face Position Selection sheet in the Group Key column.

Face 3

Type the member face with the second highest priority. This face is the third choice when the assembly is placed. Type 0 if you do not want to define another choice.

Group 3

Type the group key code. Valid codes are listed on the Face Position Selection sheet in the Group Key column.

Face 4

Type the member face with the third highest priority. This face is the fourth choice when the assembly is placed. Type 0 if you do not want to define another choice.

Group 4

Type the group key code. Valid codes are listed on the Face Position Selection sheet in the Group Key column.

Face 5

Type the member face with the lowest priority. This face is the last choice when the assembly is placed. Type 0 if you do not want to define another choice.

Group 5

Type the group key code. Valid codes are listed on the Face Position Selection sheet in the Group Key column.

Available Face Numbers

These figures show the available face numbers for common section shapes that you can type in the Face 1-5 boxes.

HSRefData_CircStrucFaceNumbers

See Also

Lookup Tables