Steel Connection Properties - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Hangers and Supports Data Driven Assembly

Language
English
Product
Intergraph Smart 3D
Subproduct
Hangers and Supports
Search by Category
Reference Data
Smart 3D Version
13.1
Standard Database for Smart Reference Data Version
2020 (12.0)

IJUAhsCornerConn1Type::Connection1Type or IJUAhsTeeConn1Type::Connection1Type

Specifies the type of connection to use when connecting Leg1 to Member1. Applicable to U, L, T, and Box Frame types only. Allowed values are from the hsSteelCornerConnection or hsSteelTeeConnection codelist in the HS_S3DAssy_Codelist.xls workbook. These values are:

  • 0 - Butted

  • 1 - Lapped

  • 2 - Nested

  • 4 - Coped

  • 5 - Mitered (Not applicable for T-Frame)

IJUAhsCornerConn1Swap::Connection1Swap

Specifies whether the connection between Leg1 and Member1 is swapped so that they are connected in the reversed order. Applicable to U, L, and Box Frame types only. This property accepts two values, 0 and 1.

0 False - Member1 connects into the section of Leg1.

1 True - Leg1 connects into the cross section of Member1.

IJUAhsCornerConn1Mirror::Connection1Mirror or IJUAhsTeeConn1Mirror::Connection1Mirror

Specifies whether to mirror the connection between Leg1 and Member1 if the connection type has a valid mirrored configuration. For a lapped connection, the steel section laps to the opposite side. For a nested connection, the steel section nests into the opposite corner if one exists. This property accepts Boolean values 0 and 1 and is applicable to U, L, T, and Box Frame types only.

IJUAhsCornerConn2Type::Connection2Type

Specifies the type of connection to use when connecting Leg 2 to Member 1. This property is applicable to U-Frame and Box Frame type. Allowed values from the hsSteelCornerConnection codelist in the HS_S3DAssy_Codelist.xls workbook are:

  • 0 - Butted

  • 1 - Lapped

  • 2 - Nested

  • 4 - Coped

  • 5 - Mitered

IJUAhsCornerConn2Swap::Connection2Swap

Specifies whether to swap the connection between Leg2 and Member1 so that they are connected in the reversed order.

0 False - Member1 connects into the section of Leg2.

1 True - Leg2 connects into the cross section of Member1.

IJUAhsCornerConn2Mirror::Connection2Mirror

Specifies whether to mirror the connection between Leg2 and Member1 if the connection type has a valid mirrored configuration. For a lapped connection, it laps to the opposite side. For a nested connection, it nests into the opposite corner if one exists. This property accepts Boolean values 0 and 1.