Duct run to duct run connections - Intergraph Smart 3D - Help

Intergraph Smart 3D HVAC

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Help
Smart 3D Version
12.1 (2019)

No.

Route Object

Approval Status

Permission Group Access

1

Duct run A

Working

Full control/ Write

2

Duct run B

Non-working

-

Result: If you delete duct run A, the software also deletes all associated connections.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Duct run A

Working

Full control/ Write

2

Duct run B

Non-working

-

3

Reducing transition associated with duct run B

Result: If you delete duct run A, the software also deletes all associated connections.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Duct run A

Working

Full control/ Write

2

Duct run B

Non-working

-

3

Reducer associated with duct run A

Result: If you delete duct run A, the software also deletes all associated objects and connections.

Before deletion

After deletion