General Tab (Insert Component Properties Dialog) - Intergraph Smart 3D - Help

Intergraph Smart 3D HVAC

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Help
Smart 3D Version
12 (2018)

Creates or modifies property values or displays status information about an object. The properties that display depend on the reference data defined for the object.

Duct Run

Specifies the name of the duct run associated with the feature. You can select another run from the list if necessary.

<Load More Runs> loads all the runs that belong to the parent system. This option is not available after you load all the runs, or if the parent system contains less than 200 runs.

More displays the Select Duct Run Dialog. Use this option to select a duct run that is associated with a different ducting system.

Insulation Material

Specifies the material of the insulation.

Piping

If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Material box. However, if you manually entered the insulation specification, you must provide a corresponding insulation material as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding material as per the specification.

HVAC

If you select Not Insulated, you cannot change the information in Insulation Thickness.

Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.

Insulation Thickness

Specifies the thickness of the insulation.

Piping

If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Thickness box. However, if you manually entered the insulation specification, you must provide a corresponding insulation thickness value as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding thickness value as per the specification.

HVAC

If you selected Not Insulated in the Insulation Material box, this property is unavailable.

Name

Displays the name assigned to the in-line component.

Part

Displays the part description assigned to the in-line component.

Number of Vanes

Specifies the number of vanes used for branches during routing. To add the weight and center of gravity of the branches vanes in the branches feature calculations, assign the values for the duct material and thickness of the branches feature as the values for the vane material and thickness equals (that is, these values are equal). The range of values for Number of Vanes includes non-negative integers.

Vane Length

Specifies the length of the specified vanes.