Allows you to set options for adding a straight feature into a duct run.
Duct Run
Defines the duct run to which the straight feature belongs.
Material
Defines the material of which the straight feature is constructed.
Thickness
Defines the thickness of the straight feature material.
Insulation Material
Specifies the material of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Material box. However, if you manually entered the insulation specification, you must provide a corresponding insulation material as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding material as per the specification.
HVAC
If you select Not Insulated, you cannot change the information in Insulation Thickness.
Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.
Insulation Thickness
Specifies the thickness of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Thickness box. However, if you manually entered the insulation specification, you must provide a corresponding insulation thickness value as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding thickness value as per the specification.
HVAC
If you selected Not Insulated in the Insulation Material box, this property is unavailable.
Length
Defines the length for the straight feature (for example, 1 ft. 1.06 in).