Reviews and modifies end features or components.

Properties

Opens a dialog box with properties for the selected feature. Allows you to review the properties of the selected feature and change the value assigned to a property.

Move From

Defines the origin of the move vector. If you do not define a starting point, the current location of the end feature is assumed to be the starting point.

Move To

Defines the termination point of the move vector.

When you move, or modify a route object in HVAC, Electrical, or Piping, Smart 3D treats any unfinished ends as free end features. An unfinished end is an end with mating parts or a logical data connection with one logical port. You can reconnect using these free end features. This behavior allows you to reuse existing mating parts and connections and reduces wait times.

Plane

Plan Plane

Defines the work surface as the XY plane at the depth of the active end. You also can press CTRL+1 to select this option.

Elevation Plane: East-West ( Z Plane: X-Axis)

Defines the work surface as the XZ plane. You also can press CTRL+2 to select this option.

Elevation Plane: North-South ( Z Plane: Y-Axis)

Defines the work surface as the YZ plane. You also can press CTRL+3 to select this option.

Plane by Turn/Branch

Defines the work surface as the plane defined by an existing turn or branch. You select the turn or branch to set the plane. You also can press CTRL+4 to select this option.

Plane by Three Points

Defines the work surface using three points that you define. You also can press CTRL+5 to select this option.

No Plane

Clears any work surfaces. The software does not project points that you place to any plane. You also can press CTRL+6 to select this option.

Run

Specifies the name of the duct run associated with the branch. You can select another run from the list if necessary.

<New Duct Run> displays the New Duct Run dialog box. Use this option to create a new duct run.

<Select Graphically> allows you to select an existing run in a graphic view, or the Workspace Explorer.

<Load More Runs> loads all the runs that belong to the parent system. This option is not available after you load all the runs, or if the parent system contains less than 200 runs.

More displays the Select Duct Run Dialog. Use this option to select a duct run that is associated with a different ducting system.

Part

Defines the part assigned to the end feature.

Lock

Turns on or off locking for the angle. If the angle is locked, the angle at the other end of the leg is fixed at the value in the Angle field.

Leg Angle

Defines the angle of the leg end feature.

Rotate

Allows you to rotate the end feature.

Rotation Angle

Defines the rotation angle for the end feature.

Length Lock

Locks or unlocks the Length box.

Length

Defines the length for the end feature. You can enter any value needed, provided it does not conflict with the defined specifications. If the Length Lock is unlocked, this box displays the dynamic readout of the current end feature length.

Offset

Defines the distance for offset that the software uses during feature placement. The reference is centerline, width, or depth). The route plane does not have to be active to locate the offset from the plane point.