General Tab (Conduit Straight Feature Properties Dialog) - Intergraph Smart 3D - Help

Intergraph Smart 3D Electrical

Language
English
Product
Intergraph Smart 3D
Subproduct
Electrical
Search by Category
Help
Smart 3D Version
12.1 (2019)

Displays and defines the general properties of the selected conduit straight feature.

Standard

System

Displays the system to which the straight feature belongs. You cannot change the system of the straight feature.

Conduit Run

Specifies the conduit run to which the straight feature belongs. You can select another run if necessary.

<Load More Runs> loads all the runs that belong to the parent system. This option is not available after you load all the runs, or if the parent system contains less than 200 runs.

More displays the Select Conduit dialog. Use this option to select a conduit run that is associated with a different conduit system.

Specification

Specify the active conduit specification for the straight feature. All conduit specifications that are allowed for the system parent of the conduit run display for selection. If appears in the box, the conduit specification is inherited from the conduit run to which the straight feature belongs. If the icon does not appear and you want to use the conduit specification from the conduit run, select Use Run Specification.

Nominal Conduit Diameter

Specifies the nominal diameter (NCD) of the straight feature. If displays in the box, the NCD for the straight feature is inherited from the conduit run to which the straight feature belongs. If the icon does not display, and you want to use the conduit specification from the conduit run, select Use Run NCD. If you have manually selected the part, the NCD of the selected part displays and you cannot change it.

Type

Specifies the types of straight features allowed by the selected Specification and Nominal Conduit Diameter. Straight features are listed by short codes. You can change the straight feature type if needed. If you have manually selected the part, this box displays Part selected manually and cannot be changed.

Option

Specifies a list of available straight features. The software generates this list based on the conduit specification, the NCD, and the short code that you selected in the Type box. If you have manually selected the part, this box displays Part selected manually and cannot be changed.

Base Part Name

Displays the part name for the straight feature. The software selects the part number using the conduit specification guidelines. Click Select Manually to override the conduit specification, and select the part number from the catalog. If you select a part manually, the Nominal Conduit Diameter, Type and Option properties are disabled.

Length

Specifies the length of the straight feature. You cannot change the length of the straight feature.

Fill Information

Percent Fill

Displays or defines the percent cable fill in the conduit feature.