Honor Maximum Offset for Grouping - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Drawings and Reports Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Reference Data
Smart 3D Version
12 (2018)

Specifies whether the software honors the offset value for the Maximum Offset for Grouping property. When selected, this option honors the offset distance, forcing the software to create separate labels when the distance between consecutive endpoints of linear objects is greater than the Maximum Offset for Grouping.

  • Select this option to honor the offset distance. This is the default setting.

  • Clear this option to ignore the offset distance.

  • You cannot set an offset value in the Maximum Offset for Grouping property if the Honor Maximum Offset for Grouping property is cleared. For more information, see Maximum Offset for Grouping.

  • The End of Segment (DrawingGAEndOfSegment) geometric analyzer uses the Honor Maximum Offset for Grouping property.

  • The following options are available for manually editing the .xml file.

    • Type -1 to ignore the offset distance.

    • Type 0 to honor the offset distance.

  • Enclose either of the above options within the following .xml tags.

<ignoreOffsetForGrouping>0