A straking Seam does not have a related StrakingSplit_AE - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12.1 (2019)

Message

A straking Seam does not have a related StrakingSplit_AE.

Severity

High.

Detailed Description

A straking seam does not have a related straking split active entity (AE). Possible situations:

  • Missing the StructSplit_OPER1 relationship to PlateStrakingSplit_AE for straking seams.

  • Missing the StructSplit_OPER1 relationship to ProfileStrakingSplit_AE for straking seam point.

Possible Cause

Unknown.

Possible Impacts

The split will not work.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the object, and modify it, if necessary. Or, select the object, and perform a re-computation to update it.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.