The pipe part is missing a connection to the fitting - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12.1 (2019)

Message

The pipe part is missing a connection to the fitting.

Severity

Crucial.

Detailed Description

To allow a fitting placed by Hole Management to be spooled, a connection must exist between the pipe part and the fitting. The pipe part is missing the connection to the fitting of the hole in error that allows the fitting to be spooled along with the pipe part.

Possible Cause

The hole may have been created in an older version of the software, and the migration command failed to create the connection.

Possible Impacts

If the connection does not exist, then the fitting cannot be spooled with the pipe part.

What You Should Do

  1. Open the model.

  2. Run the HoleMgmt V6 middle tier migration command (HMV6Migration.HoleFittingPartsMigration).

This command updates the older objects with the new relationship.