Stair or Ladder has more than one related reference plane or edge - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12 (2018)

Message

Stair or Ladder has more than one related reference plane or edge.

Severity

Normal.

Detailed Description

A stair or ladder has multiple relationships to a reference edge or plane. The location of the stair or ladder depends on the inputs; therefore, more than one input would make the location of the ladder ambiguous.

Possible Cause

Unknown.

Possible Impacts

It is highly likely that one would not even notice a problem with the behavior of the ladder or stair because the first encountered input would be used, and any additional inputs would be ignored. However, it is plausible that if any of the inputs get modified, the ladder could compute its location based off a different input. The ladder would seem to move around unpredictably.

What You Should Do

Manually update the ladder or stair.

  1. Ask your database administrator to back up the model.

  2. Send the database backup to Hexagon Asset Lifecycle Intelligence Support.

  3. Open the model.

  4. Select the ladder or stair.

  5. On the ribbon, click Select Reference Edge .

  6. In a graphic view, select a new reference edge for the stair or ladder.

  7. Click Finish on the ribbon.