End frame connection missing a relation to the supporting member joint - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12 (2018)

Message

End frame connection missing a relation to the supporting member joint.

Severity

Crucial.

Detailed Description

An axis-end or axis-collinear frame connection is missing a relationship to the supporting member axis joint.

Possible Cause

Unknown.

Possible Impacts

Cannot properly copy an axis-end or axis-collinear connection when attempting to establish a new parent for the frame connection For example, copying/pasting the supported member of a collinear connection along with the collinear frame connection will not provide you with the opportunity to choose the end of the supporting member system in which to establish the connectivity.

What You Should Do

The frame connection needs to be removed and re-created.

  1. Ask your database administrator to back up the model.

  2. Supply all information possible that might have led to this situation, and submit this information along with the backup to Hexagon Asset Lifecycle Intelligence Support.

  3. Open the model.

  4. Locate the offending frame connection, and delete it from the model.

  5. Select the member part, and then click the member End on the member ribbon to re-create the frame connection.

  6. Change the frame connection type back to the axis-end/axis-collinear connection, and graphically select the supporting member to complete the frame connection modification.