Message
LinearExtrusion AE does not have a retrievable MotherCurve.
Severity
Fatal.
Detailed Description
The naming of symbol information used to create the Linear Extruded Plate must be consistent. For example, the RelationshipName of the First ProxyOwner needs to be the same as the RelationshipName for the StructContour in the FromOutputColltoOutputs.
Possible Cause
Unknown.
Possible Impacts
You cannot manipulate the objects or objects related to it.
What You Should Do
-
Open the model.
-
In the Molded Forms task, select the object from the To Do List or Workspace Explorer, and modify it, if necessary. Or, select the object, and perform a re-computation to update it.
-
Re-run the Check Database Integrity custom command and the DBIntegrity report.
-