Permission Group of the shape is different from the corresponding Smart Equipment - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12 (2018)

Message

Equipment Unspecified Error 2 (Permission Group of the shape is different from the corresponding Smart Equipment).

Severity

Crucial.

Detailed Description

The permission group of a shape should be the same as the corresponding smart equipment.

Possible Cause

Copying the shapes of design equipment to another design equipment in a different permission group. Then, the shape in the design equipment does not have the same permission group as that of its parent design equipment.

Possible Impacts

This problem prevents the deletion of the equipment because you do not have permission to the permission group of the child (shape).

What You Should Do

Run the Clean Database custom command, which sets the Equipment permission group to the shape.