Load case does not have a parent load case folder - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

Load case does not have a parent load case folder.

Severity

High.

Detailed Description

Load cases have a parent load case folder assigned to a plant or ship model. A load case cannot exist in the model without this association to this load case folder.

Possible Cause

It is unknown how this condition can occur because the relation to the load case folder may only be removed by deleting the load case or the plant or ship model. Because the load case still exists, the load case was obviously not deleted. Also, the model cannot be removed so it is not known how this relationship was severed.

Possible Impacts

The load case will be ignored; hence, the loads associated to the load case will also be ignored.

What You Should Do

The load case should be removed and re-added. Use the Clean Database custom command to remove this load case.

  1. Ask your database administrator to back up the model.

  2. Supply all information possible that may have led to this situation, and submit this information along with the backup to Intergraph Process, Power & Marine Support.

  3. Using the Clean Database custom command, remove this load case.