Member part cutLength is zero - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

Member part cutLength is zero.

Severity

High.

Detailed Description

A member part has a cut length less than or equal to zero.

Possible Cause

The member part or system was manipulated such that the part axis is zero in length. This problem could have been due to a direct manipulation of the end of the member part, making the start and end point coincident, or as a result of an indirect modification that forced the ends of the member part to be coincident.

Possible Impacts

Unknown.

What You Should Do

Remove the member part, or move the part such that its ends are no longer coincident.

  1. Open the model.

  2. Locate the offending member part, and move or modify it such that its end points are no longer coincident.