Error code 103 - unspecified error description (Footings) - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

Error code 103 - unspecified error description

Severity

High

Detailed Description

A footing exists but has no corresponding entry in the CoreSpatialIndex table

Possible Cause

A component based footing was placed in the previous version of the software.

Possible Impacts

Footing cannot be selected through the volume filters.

What You Should Do

Run the DBI script to correct these footings. The script accumulates the range of all of the footing’s outputs and assigns it to the parent footing.