Message

Control point does not have a parent.

Severity

Crucial.

Detailed Description

A control point should have a parent for it to exist. A control point cannot exist by itself without a parent.

Possible Cause

Coding or data model propagation errors in an earlier version.

Possible Impacts

A control point created without a parent is useless and cannot be used further.

What You Should Do

The control point object needs to be removed.

  1. Open a session.

  2. In order to select the control points that do not have a parent, a combination of filters can be used. Create an object type filter with control point as object type. (Name this filter Filter1.)

  3. Create a properties filter with the following parameters. (Name this filter Filter2.)

    • In the Object type used as the basis for property identification box, select Control points.

    • In the Relationship box, select Object to Control Point.

    • In the Related object box, select Equipment.

    • In the Display properties in this category box, select Standard.

    • Select Approval Status as the property.

    • Set Approval Status = Working.

    • Set Approval Status <> Working in the second row of the grid.

    • Select the Match Any radio button.

  4. Create a Compound Filter with the following combination: Filter1 AND Not Filter2. Name the compound filter Comp1.

  5. Use the Select by Filter command with the newly created Comp1 to select all control points that do not have a parent.

  6. Delete all of the control points that do not have a parent.