Corrupted Hanger Connections - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13

Message

Corrupted Hanger Connections.

Severity

High.

Detailed Description

There are two types of hanger connection objects:

  • Intermediate connection objects are related to support components.

  • External connection objects are related to route objects.

The hanger connection object also has a relation to the route object.

This error identifies the parent support objects whose external connection objects are not related to a route object. It also identifies support objects not having external connection objects.

Possible Cause

Some workflows in the route task may have caused the connection to lose its relation to the route object.

Possible Impacts

Hanger connections will be recreated the next time the support object is recomputed if the connections do not exist or if they do not have the required relations. This DBI script detects and repairs the hanger connections at an early stage before the support object is recomputed.

What You Should Do

  1. Open the model.

  2. Backup the model.

  3. Run the DBI command to detect the support object whose hanger connections are not working or are not present.

  4. Run the DB Clean command to repair the problematic support object, creating hanger connections with the required relations.

  5. Save the session.