Physical connection only has dummy symbol - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13

Message

Physical connection only has dummy symbol.

Severity

Crucial

Detailed Description

A physical connection only has one symbol, and it is a dummy symbol associated with a dummy selection rule.

Possible Cause

Unknown

Possible Impacts

  • You cannot open the Properties dialog box for the physical connection.

  • Cannot manufacture the corresponding part.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. Open the model, and verify that the corresponding part is not on the To Do List.

    If the part is on the To Do List, you need to identify the cause and provide a solution; otherwise, the connection could get deleted.

  3. Run the Clean Database custom command.

  4. Check the box beside the physical connections to be fixed, and then click run Clean Now.