Error code 58 - unspecified error description - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

Error code 58 - unspecified error description.

In V7, this message will be Shape has Invalid Range.

Severity

High.

Detailed Description

A shape has an invalid range.

Possible Cause

This problem occurs when migration asks for the range of one of the shapes that are imported from a SAT file. Historically, some SAT file imports have generated this kind of shape. The SAT file import process has now been improved to prevent creating such shapes, but the existing shapes will still log these errors.

Possible Impacts

The shapes are no longer usable. They cannot be selected or located. It is not possible to repair these shapes.

What You Should Do

  1. Open the model.

  2. Delete the shape(s).

  3. Save the session.

  4. Refresh all session files with a workspace that includes the equipment.