Check and Repair Non-Selectable Region Connections - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

Inverted Regions are not selectable while modifying intersection connection, should be repaired.

Severity

Crucial

Comment

Region Connections with invalid locate control flags.

Detailed Description

This script finds and repairs all the region connections that are not selectable while modifying the intersection connections.

Possible Cause

Unknown

Possible Impact

You cannot select region connections while modifying intersection connections.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. In the Project Management task, select the model, and then click Database > Integrity.

  3. In the Check Data Consistency dialog box, select Basic check, and then click Run.

  4. In the S3DHost task, run the Clean Database (SP3DCleanDatabaseCmd.CCheckObj) custom command on the model database.

    The software displays the objects to be repaired.

  5. Select the objects with the Inverted Regions are not selectable while modifying intersection connection, should be repaired description and Region Connections with invalid locate control flags comment.

  6. Click Clean.

    The software repairs the selected objects.