PDMS Import Validation Command - Intergraph Smart 3D - Help

Intergraph Smart 3D Common

Language
English
Product
Intergraph Smart 3D
Subproduct
Common
Search by Category
Help
Smart 3D Version
13

Validates the mapping data that you have defined in the PDMSS3DImportMapping.xls workbook. The File > Import > PDMS Datal Import > PDMS Import Validation command uses a specified set of user-defined criteria to locate missing mapping details, and then updates the mapping file.

During the validation process, Smart 3D updates individual worksheets with any missing mapping information. For identification, the software highlights the updated cells in red or yellow. A new sheet in the mapping file, Smart 3D Objects - Missing Mapping, lists all of the missing mapping information.

After running the validation tool, you must bulkload the PDMSPropertySchemaDefinition.xls workbook into the Smart 3D catalog. This bulkload is required to add the PDMS interfaces to the Smart 3D catalog, and to update the Smart 3D property dialog boxes with the PDMS category.

The software writes the results of the validation process to a log file.

Validation criteria

Hierarchy

Validates site, zone, and UDET data in the specified .datal file. The software updates the PDMSPropertySchemaDefinition.xls workbook with InterfaceName and PDMS AttributeName for attributes under Site, Zone, and UDET. The software also updates the HierarchyClassMap sheet in the PDMSS3DImportMapping.xls workbook with missing attributes of UDET data.

Equipment

Validates equipment, sub-equipment, nozzle, and primitive data in the specified .datal file.

The software updates the PDMSPropertySchemaDefinition.xls workbook with InterfaceName and PDMS AttributeName for attributes under Equipment, Sub-Equipment, Nozzle, and Primitive. The software also updates the following sheets in the mapping workbook:

  • CPSmartEquipmentMap - Missing attributes of PDMS equipment.

  • CPEquipmentComptMap - Missing attributes of PDMS sub-equipment.

  • CPShapeMap - Missing attributes pf PDMS primitives.

  • CPShapeValueMap - Missing Part types of PDMS Primitives.

  • CPPipeNozzleMap - Missing attributes of PDMS.

  • NozzleAdditionalAttrMap - Missing PDMS CATReference for nozzles.

  • PartNumberValueMap - Missing PDMS SpecReference of equipment and sub-equipment data.

  • AspectMap - Missing LEVEL and OBST values of PDMS primitives.

Piping

Validates PDMS pipeline, pipe branch, pipe component, pipe instrument, and pipe support data in the specified .att file. For the piping discipline, the software automatically selects the .att file from the specified .dtl file location. The name of the .dtl file and the .att file must be the same. Both files must be in the same folder.

The software updates the PDMSPropertySchemaDefinition.xls workbook with InterfaceName and PDMS AttributeName for attributes under Pipeline, Pipe Branch, Pipe Component, Pipe Instrument, and Pipe Support. The software also updates the following sheets in the mapping workbook:

  • CPPipelineSystemMap - Missing attributes under PDMS Pipeline system in the .att file.

  • CPMPipeRunMap - Missing attributes under the PDMS branch in the .att file.

  • PipeRunSpecMap - Missing Pipe Specification (PSPE) of the PDMS branch in the .att file.

  • PipeComponentAttrsMap - Missing attributes under PDMS Pipe Components in the .att file.

  • PipeInstrumentAttrsMap - Missing attributes under PDMS Pipe Instruments in the .att file.

  • PipeSupportAttrsMap - Missing attributes under PDMS Pipe Supports in the .att file.

  • S3DXMLPartTypeMap - Missing Components GType for Pipe Component, Pipe Instrument, and Pipe Support.

  • SPREFS3DIdentifierPatternMap - Missing SPECReference (SPRE) for Pipe Component, Pipe Instrument, and Pipe Support.

  • RunChangeComponentsMap - Missing SPECReference (SPRE) for Pipe Runchange Components (reducer and tee).

HVAC

Validates PDMS HVAC system, HVAC branch, HVAC component, and HVAC fitting data in the specified .att file. For the HVAC discipline, the software automatically selects the .att file from the specified .dtl file location. The name of the .dtl file and the .att file must be the same. Both files must be in the same folder.

The software updates the PDMSPropertySchemaDefinition.xls workbook with InterfaceName and PDMS AttributeName for attributes under HVAC System, HVAC Branch, HVAC Component, and HVAC Fitting data. The software also updates the following sheets in the mapping workbook:

  • CPDuctingSystemMap - Missing attributes under PDMS HVAC System in the .att file.

  • CPDuctRunMap - Missing attributes under PDMS HVAC Branch in the .att file.

  • HVACRunSpecMap - Missing HVAC Branch specifications (PSPE) in the .att file.

  • HVACRunMaterialMap - Missing HVAC Branch specifications (PSPE) in the .att file.

  • DuctComponentAttrsMap - Missing attributes under PDMS HVAC Components in the .att file.

  • DuctFittingAttrsMap - Missing attributes under PDMS HVAC Fitting in the .att file.

  • S3DHVACXMLPartTypeMap - Missing Component GTypes of HVAC Components and HVAC Fittings in the .att file.

  • SPREFS3DHVACIdentifierPttrnMap - Missing SPECReference (SPRE) of HVAC Component and HVAC Instrument in the .att file.

Electrical

Validates PDMS cableway system, cableway branch, and cableway fitting data in the specified .att file. For the Electrical discipline, the software automatically selects the .att file from the specified .dtl file location. The name of the .dtl file and the .att file must be the same. Both files must be in the same folder.

PDMS does not currently have a keyword for electrical. Because electrical data is in the form of new pipe, the software validates cable way data in the pipe class mapping sheets.

PDMS Properties Extractor Dialog

What do you want to do?