  1. In the tree view, click Piping > Piping Specification > Model Rules > Size Reduction Rule.

  2. Click the Insert Row Command to insert a blank row in the grid view.

  3. Select the size reduction type (concentric or eccentric).

  4. Enter the first and second sizes for the size reduction rule.

  5. Enter the second fitting's first size.

  6. Optionally, enter the third and fourth fittings' first size.

  7. Optionally, enter the size reduction preference order.

The Size Reduction Rule sheet in the workbook corresponds to the Size Reduction Rule node. See Piping Reference Data.