Define Joint Quality Factors - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
13.1
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Joint Quality Factor.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Nominal Piping Diameter From column, type the nominal pipe diameter (NPD) that specifies the start of the joint quality factor range.

  5. In the Nominal Piping Diameter To column, type the NPD that specifies the end of the joint quality factor range.

  6. In the NPD Unit Type column, type the units for the NPDs. For example, type mm or in.

  7. In the Joint Quality Factor column, type the joint quality factor, as a percentage, that you want to use for the defined NPD range.

The Joint Quality Factors sheet in the Piping Materials Class.xls workbook corresponds to the Joint Quality Factor node in the Catalog task. See Piping Reference Data.