In the tree view, click Piping > Piping Specification > Model Rules > Bolt Diameter Equivalence Rule.
-
Click the Insert Row Command to insert a blank row in the grid view.
-
In the Bolt Diameter In Primary Units column, enter the bolt diameter in the first unit of measurement.
-
In the Bolt Diameter In Secondary Units column, enter the bolt diameter in the second unit of measurement.
-
In the Primary Units of Measure column, enter the unit of measurement, mm or in for example, for the values in the Bolt Diameter Primary Units column.
-
In the Secondary Units of Measure column, enter the unit of measurement, mm or in for example, for the values in the Bolt Diameter Secondary Units column.
-
Click the Save Command .
-
The Bolt Diameter Equivalence Rule sheet in the Bolt Diameter Equivalence.xls workbook corresponds to the Bolt Diameter Equivalence Rule node. See Piping Reference Data.