Main isolation – Valves (table 2) - HxGN EAM - 11.07.01 - Feature Briefs - Hexagon

HxGN EAM Mobile for Transit Map View Main Isolation Functionality Guide

Language
English
Product
HxGN EAM
Search by Category
Feature Briefs
HxGN EAM Version
11.7.1

The values stored in this table indicate the two blocks which correspond to each isolation valve within the network. The relationship between the valves and blocks is strictly 2:1; that is, each valve will be associated with two blocks (i.e. There will always be one block on either side of the valve. Please note that the order (i.e. Left-right; upstream-downstream, etc.) in which these two adjacent blocks are associated with a given valve record in Table 2 does not matter. The number of records in Table 2 will be equal to the number of valve features in the network. Additionally, Table 2 must also document the unique GISOBJID (i.e. the value of the GISID field in the EAM equipment record) for each valve feature represented in the user’s GIS network.