Manually Create or Update Alternate Structure Details - EcoSys - 3.01 - Administration & Configuration - Hexagon PPM

EcoSys Core and Projects Administration (3.01)

Language
English
Product
EcoSys
Search by Category
Administration & Configuration
EcoSys Standard Version
3.01

The Alternate Structure tab allows an EcoSys administrator to build an enterprise-level alternate project structure. New rows may be inserted either at or below the structure element currently selected. Fields may be populated by either typing and tabbing between fields, or directly selecting fields and entering required data.

  1. Navigate to Admin > Projects Admin > Maintain Alternate Structures.

  2. At the top of the screen, in the green parameter bar, click the Alternate Structure ellipsis to select the required alternate structure type.

  3. Click the Refresh button.

  4. Click the Alternate Structure tab.

  5. Click the Rows icon and select Insert Under. This creates a new row under the selected line item.

    The Insert Under places the project structure below the selected line item. If the Insert Row icon is used, the project structure is placed at the same level as the selected line item. Hence it is recommended to use Insert Under.

  6. Type in the required ID.

  7. Type in the required Name.

  8. Click the Parent ID ellipsis to select the required parent.

  9. Click the Save button. The full Path ID auto-populates.