Tbend - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

For ISO 14692 2017, defines the wall thickness, tbend, of the bend.

Typical units (depending on your unit system):

  • in

  • mm

  • cm

The code uses Tbend to calculate the average wall thickness (tb) of the reference laminate:

tb = (2b/a)(tbend + toverlay) + [1-(2b/a)]tbend

where a is the bend angle. For more information, see Angle 1, 2, 3.

  • If you do not define Tbend, then the software uses the pipe wall thickness, Wt. For more information, see Wt/Sch.