Full Length in Longitudinal Direction (2*Cxp) - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

If the attachment is square or rectangular instead of a nozzle, enter Cxp, the full length of the square or rectangular reinforcing pad in the longitudinal direction of the vessel. At the junction of the attachment with the vessel, the pad is converted to an equivalent round pad with the following outside radius:

ro = Sqrt(Cxp * Cyp)

This value is only used when PD5500 Annex G is True on the Home tab.