Specifies the flange yield stress at the cold (ambient) temperature and at each of the operating temperatures, for use in calculating the flange allowable stress.

Typical units (depending on your unit system):

  • lb/in2

  • KPa

  • N/mm²

Flange evaluation is based on a specific load case temperature. To evaluate the flanges in a model, specify the operating temperature at which the software evaluates the flanges in the Flange Analysis Temperature box on the Load Cases tab of the Static Analysis - Load Case Editor.