Controls options for reviewing intersection, weld joint, and threaded joint SIFs. The active properties vary based on the select type and piping code.
-
After finishing your review and closing the dialog, you have the option of transferring values to the appropriate properties on the Classic Piping Input Dialog Box.
-
B31J provides directional stress intensification factors and flexibility factors. The software uses the highest in-plane or out-of-plane SIF when the piping code defines a stress equation that uses a single SIF. The software uses the flexibility factors for the specified orientation.