B31J - Review Intersection SIF, Index, & Flexibility Dialog - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

Controls options for reviewing intersection, weld joint, and threaded joint SIFs. The active properties vary based on the select type and piping code.

  • After finishing your review and closing the dialog, you have the option of transferring values to the appropriate properties on the Classic Piping Input Dialog Box.

  • B31J provides directional stress intensification factors and flexibility factors. The software uses the highest in-plane or out-of-plane SIF when the piping code defines a stress equation that uses a single SIF. The software uses the flexibility factors for the specified orientation.