User SIFs - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

Specifies that you are defining or overwriting the calculated stress intensification factors.

Click Edit to open the User SIFs Dialog. A check next to Edit displays when you save values to the dialog.

  • B31J provides directional stress intensification factors and flexibility factors. The software uses the highest in-plane or out-of-plane SIF when the piping code defines a stress equation that uses a single SIF. The software uses the flexibility factors for the specified orientation.

  • This property does not display for FRP piping codes.