Select True when the nozzle has a pad. Select False if there is no pad.
For WRC 107/537, the software performs two separate analyses:
-
Using the nozzle OD and the vessel wall thickness plus the reinforcing pad thickness.
-
Taking the pad into account by making the nozzle OD equal to the reinforcing pad diameter and assuming a sold attachment.