User-Defined Lateral "K" - CAESAR II - Help

CAESAR II Users Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
11.0 (2019)

Specifies the soil stiffness perpendicular to the pipe axis on a stiffness per length basis. This stiffness value acts in both directions perpendicular to the pipe. This option is required if Soil Model No. is set to 1; otherwise, leave this option blank.

The smallest allowable non-zero value is 0.5.