Specifies the modulus correction divisor.

Typical units (depending on your unit system):

  • lb/in²

  • N/mm²

  • KPa

IGE/TD/12 Section A5.6 requires that the allowable fatigue stress (as specified in the fatigue curves) be adjusted by the ratio of the material modulus of elasticity divided by 209´103 N/mm2. This divisor can be adjusted if necessary by changing the entry in the Modulus Correction box.