Specifies the method used to compare the actual nozzle loads to the defined limits. Available choices are:

Absolute

Each load is compared directly to the corresponding limit. That is, FX to FX_allowable, FY to FY_allowable, and so on.

|Fa| £ |Fal|

|Fb| £ |Fbl|

|Fc| £ |Fcl|

|Ma| £ |Mal|

|Mb| £ |Mbl|

|Mc| £ |Mcl|

SRSS

The square root sum of the squares (SRSS) of each load divided by the corresponding allowable is compared to 1.0.

Forces

Forces Equation Ceasar 2

and

Moments

Moments Equation Caesar II

Unity Check

The sum of the three forces and three moments, each divided by their respective allowables is compared to 1.0.