Displays the percent of the total system mass/force included in the extracted modes, and the percent of system mass/force included in the missing mass correction (if any) for each of the individual shocks of the dynamic load cases. The value gives an indication of the accuracy of the total system response captured by the dynamic model, with 100% being the ideal.
% Mass Included
Shows the percentage of mass active in each of the X, Y, and Z directions.
% Force Active
Shows the value that is computed by taking the algebraic sum in each of the global directions, and then applying the SRSS method to each of the three directions. The sums of the three directions are added vectorally.
% Force Added
Shows the value obtained by subtracting % Force Active from 100.