F1, F2, ... F9 - CAESAR II - Help

CAESAR II Users Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
11.0 (2019)

Specifies the stress range reduction factor for most piping codes.

B31.1

Stress range reduction factor is obtained from equation 1c. Consult the applicable piping code for methods of combining cycle life data where several thermal states exist and where the number of thermal cycles is high. The software assumes a value of one if you do not type a value.

B31.3

Stress range reduction factor is obtained from equation 1c corresponding to Fig 302.3.5. If certain criteria are met, then the stress range reduction factor can exceed 1.0. The number of cycles can be specified in this box for B31.3. This allows CAESAR II to compute the cyclic reduction factor according to equation 1c.

B31.4, B31.4 Chapter XI

Stress range reduction factor is obtained from the equation given in Section 403.3.2. The number of cycles can also be specified in this box for B31.4 which allows CAESAR II to compute the cyclic reduction factor according to the equation. The fatigue factor cannot exceed 1.2.

B31.4 Chapter IX

Not used.

B31.8

Stress range reduction factor is obtained from the equation given in Section 833.8(b). The number of cycles can be specified in this box for B31.8 which allows CAESAR II to compute the cyclic reduction factor according to this equation.

B31.8 CHAPTER VIII

Not used.

B31.9

References B31.1 for detailed stress analysis. For more information, see Paragraph 919.4.1.b.

CODETI

Called U in the code.

NORWEGIAN

Called fr in the code. This value can be as high as 2.34.

DNV

Material ultimate tensile strength at temperature.

CAN Z662

F1 = L - The location factor from Table 4.2

F2 = T - The temperature derating factor from Table 4.4

For F1 = L:

Application

CLASS 1

CLASS 2

CLASS 3

CLASS 4

Gas (non-sour)

General & Cased crossings

1.000

0.900

0.700

0.550

Roads

0.750

0.625

0.625

0.500

Railways

0.625

0.625

0.625

0.500

Stations

0.625

0.625

0.625

0.500

Other

0.750

0.750

0.625

0.500

Gas (sour service)

General & Cased crossings

0.900

0.750

0.625

0.500

Roads

0.750

0.625

0.625

0.500

Railways

0.625

0.625

0.625

0.500

Stations

0.625

0.625

0.625

0.500

Other

0.750

0.750

0.625

0.500

HVP

General & Cased crossings

1.000

0.800

0.800

0.800

Roads

0.800

0.800

0.800

0.800

Railways

0.625

0.625

0.625

0.625

Stations

0.800

0.800

0.800

0.800

Other

0.800

0.800

0.800

0.800

LVP

Uncased railway crossings

0.625

0.625

0.625

0.625

All others

1.000

1.000

1.000

1.000

Class 1 - Location areas containing ten or fewer dwelling units intended for human occupancy

Class 2 - Location areas containing 11 to 46 dwelling units intended for human occupancy OR

  • Buildings with more than 20 persons

  • Outside areas with more than 20 persons

  • Industrial installations

Class 3 - Location areas with more than 46 dwelling units intended for human occupancy OR institutions where rapid evacuation may be difficult

Class 4 - Location areas where buildings intended for human occupancy have 4 or more stories.

For F2 = T:

Temperature

Derating Factor T

up to 120 (C)

1.00

150

0.97

180

0.93

200

0.91

230

0.87

F3 through F9 are not used.

CAN Z662 Chapter 11

F1 - Not used.

F2 = T - Temperature derating factor obtained from Table 4.4

F3 = - FA design factor for Condition A from Table 11.1, column A

F4 = - FB design factor for Condition B from Table 11.1, column B

F5 through F9 are not used.

BS 806

Mean stress to failure in design life at design temperature. F1, F2, ... F9. This value corresponds to the nine possible thermal states.

FDBR

Identical to B31.1, unless you type the expansion coefficients directly instead of temperatures. In that case, the software cannot determine Ehot. In this case, type a value of 1.0 in the FAC box and use these boxes to specify the product of f * Ehot / Ecold for each temperature case.

SWEDISH METHOD 1

Creep rupture stress at temperature. F1, F2 ... F9. This value corresponds to the nine possible thermal states.

STOOMWEZEN

Creep related material properties as follows:

  • F1 = Rrg - Average creep stress to produce 1% permanent set after 100,000 hours at temperature (vm).

  • F2 = Rmg - Average creep tensile stress to produce rupture after 100,000 hours at temperature (vm).

  • F3 = Rmmin - Minimum creep tensile stress to produce rupture after 100,000 hours at temperature (vm).

BS 7159

Fatigue factor Kn. This value is used inversely compared to other codes so that its value is greater than 1.0. Kn is calculated as follows:

Kn = 1 + 0.25(As/sn) (log10(n) - 3)

Where:

As = stress range during fatigue cycle

σn = Maximum stress during fatigue cycle

n = number of stress cycles during design life

UKOOA

Ratio r from the material UKOOA idealized allowable stress envelope. This ratio is defined as sa(0:1)/sa(2:1) as shown on the figure below. One value should be given for each of the operating temperature cases.

IGE/TD/12

UTS value.

EN-13480

Stress range reduction factor taken from Table 12.1.3-1 (which matches the B31.1 table above) or computed from equation 12.1.3-4. You can specify the number of cycles in this box for EN-13480. This allows CAESAR II to compute the cyclic reduction factor according to equation 12.1.3-4.

GPTC/Z380

Not used.

PD-8010 (Part 1 & Part 2)

Not used.

ISO 14692

F is used in a different way. See the Reference for ISO 14692.

HPGSL

Stress range reduction factor at design temperature.

JPI

Stress range reduction factor at design temperature.