Vessel Modeled as Pipe
Vessel modeled as pipe (not rigid) P≠0, Fluid Density ≠0
Zero-Weight Rigid to Nozzle Interface Location
Nozzle Element with WRC 297 Connection Defined
Pipe element (not rigid) P≠0, Fluid Density ≠0
The vessel flexibilities are calculated and reported during error checking. These values are used automatically in the analysis. This WRC297 data is available to output in the Miscellaneous Data report.