Enter the number of hangers or cans as a positive number in the No. of Hangers at Location box.
Placing a negative number in that field allows CAESAR II to design up to that number of hangers at the location.
All other hanger design parameters are still active.
Example
Trapeze Hanger Assembly
Power Piping Springs Allowable Load Variation:15% Rigid Support Displacement Criteria: 0.05 inches |
The software designs up to three cans at the support if the load is too high for a single or double can configuration. |