2020 R1 (4.1)

Default value: No
Allowed values: No, Automatic - Pipe Breaks Only, Automatic - All Connections, Show Options

Sets the system to insert a coupling when routing components.

No

Does not add a coupling when routing components.

Automatic - Pipe Breaks Only

Adds a coupling when routing components with socket weld or threaded piping, when the pipe breaks at the maximum length. You must set the Apply Pipe Length Rule to Automatic or Show Options or couplings are not added.

Automatic - All Connections

Adds a coupling at all connections while routing.

Show Options

Displays option prompts, when routing, to insert a coupling. This happens when using socket weld or threaded piping or when the pipe breaks at the maximum length. You must set the Apply Pipe Length Rule to Automatic or Show Options or couplings are not added.