Defines general specification information.

Weight Factor

Adds margins to component weights to account for factors such as paint and weld material. For example, a value of 1.03 can be used when paint is applied to the component.

Measure-Bore

Specifies the length (measure) and nominal pipe size (bore) measurement standards used by the specification. Select Imperial-Inch, Metric-Inch, or Metric-Metric. Imperial and Inch standards are in inches. Metric standards are in millimeters.

Library sub directory

Defines the library folder that the specification uses. This folder can be anywhere on the network. The delivered libraries are LIB_I, LIB_M, and LIG_MM in [Product Folder]\Plant.

Nominal rating, Temperature, Pressure, and Flange face

Specifies values used as reference when populating information in the symbol. This value is used in CADWorx P&ID with the SpecControl startup variable.

Piping material, Forging material, Fitting material, Gasket material, Stud material, and Bolt material

Specifies the materials used when transferring information to CAESAR II. This value is used in CADWorx Plant.

Database codes

Specifies a user-defined database code file. Used with the DataBaseCodes startup variable. For more information, see Edit Component Dialog Box.

Color

Specifies the default color for the specification. Select Color opens the Select Color dialog box.