CADWorxP&ID tab: Setup > Setup
CADWorxP&ID tab: Process Lines > Setup
Setup toolbar: Setup
Line Numbers toolbar: Line Number Setup
P&ID menu: Accessory > Line Numbers > Setup
Command line: LINENUMBER
Specifies the process line numbering configuration by modifying the Project.cfg file located in the project folder. This command displays the Line Numbering System dialog box.
Category
Specifies a data column from the LINE table as defined by Column Setup in Table Setup . For more information, see Table Setup.
-
Add
Adds the selected column in Category to the bottom of the list box.
-
Delete
Deletes the column value selected in the list box.
Separator
Specifies a separator between values in the list box. Type any combination of alphanumeric and symbol characters.
-
Add
Adds the value in Separator to the bottom of the list box.
-
Delete
Deletes the separator value selected in the list box.
Default value
Specifies a default value for the column value selected in the list box.
Category (list box)
Displays column and separators values that are used for line numbering. Values appear in the line number in their top-down order in the list box. SIZE and SPEC are included by default.
System Off
Turns off the line numbering system. When the line numbering system is not used, you manually type the line number in Tag for Edit . For more information, see Edit.
System On (Dynamic Size/Spec)
Turns on the line numbering system. When the line numbering system is used, P&ID generates the line number according to column and separator values in the list box. Tag is not available for Edit . For more information, see Edit.
Move Up
Moves a category up the Category list.
Move Down
Moves a category down the Category list.
Preview
Displays a preview of the line number. Values are displayed in the order of values in the list box.
If the Project.cfg configuration file of the project is set to read-only, all fields in the Line Numbering System dialog box are inactive.