CADWorxP&ID tab: Process Lines > Tag Line
Misc toolbar: Tag Line
P&ID menu: Utility > Tag Line
Command line: TAGNUMBER
Adds a process line tag to the drawing.
The value for Tag is copied to the drawing. If the tag has no value, then the tag is placed on the drawing but will not be visible. To add a value to Tag, see Edit and Editing Line Component Dialog Box.
-
The tag and the process line are updated when either has changed. Automatic updating is not available in the CAD platform, but the CAD platform reads the information from the database.
-
Changes you make to a process line are not automatically made to the tag unless you are using a database and have the line number system turned on. For more information see, LineNumberSystem.
-
Turn on SPECASSIGNTOGGLE to automatically update tags when the spec is changed.