Body Flange - CADWorx - Help

CADWorx Equipment

Language
English
Product
CADWorx
Subproduct
Equipment
Search by Category
Help
CAESAR II Version
12
CADWorx Version
20.0 (2020)
CADWorx Structure Version
2020(4.0)

Mouse Icon Toolbar: EQP Body Flange ICON

Specifies the parameters of the body flange.

ANSI flange lookup

Displays the ANSI Flange dialog box.

Description

Specifies an alphanumeric description for the component. This description is visible even when the component is collapsed in the grid.

Length

Specifies the distance from the starting point to the ending point of the component.

Diameter Basis

Specifies either the inside or outside diameter. Select the diameter type from the list.

Diameter

Specifies the diameter of the component based on the Diameter Basis value.

Thickness

Specifies the component thickness.

Flip Orientation

Reverses the orientation of the component.

Material

Displays the Select Item dialog box, which lets you select the material from the list. For more information, see Select Item Dialog Box. The Select Item dialog box uses the file specified by the MaterialFile configuration file variable. For more information, see MaterialFile.

Body Flange Description

Flange Face ID

Specifies the component inner diameter. See dimension 1.

Flange Face OD

Specifies the component outer diameter. See dimension 2.

Flange Face Thickness

Specifies the component thickness. See dimension 3.

Gasket ID

Specifies the component inner diameter.

Gasket OD

Specifies the component outer diameter.

Gasket Thickness

Specifies the component thickness.

Flange ID

Specifies the component interior flange diameter. If you set this value to zero for a blind flange, the software disables all hub-related boxes. The hub-related boxes are enabled if the Flange ID (D) box has a value greater than zero. See dimension 4

Flange OD

Specifies the component outer diameter. See dimension 5

Flange Thickness

Specifies the component thickness. See dimension 6

Large Hub Thickness

Specifies the component thickness. See dimension 7.

Small Hub Thickness

Specifies the component thickness. See dimension 8

Hub Length

Specifies the distance from the starting point to the ending point of the component. See dimension 9.

Insulation

Displays the Insulation dialog box. For more information, see Insulation Dialog Box.

ANSI Flange Dialog Box

Specifies parameters for ANSI flanges. This dialog box lets you select an ANSI flange and then populates the body flange dimension boxes automatically. The flange data is read from the [Product Folder]/Equipment/System/BodyFlangeImperial.DAT file.

Flange Series

Specifies the series associated with the flange. Select a series from the list.

Flange type

Specifies the type associated with the flange. Select a type from the list.

Flange rating

Specifies the rating associated with the flange. Select a rating from the list.

Nominal Diameter

Specifies the nominal diameter associated with the flange. Select a diameter from the list.

Bore Diameter

Specifies the bore diameter associated with the flange.

Flange Blind

Specifies whether the flange is a blind flange.